Deepwave Microwave Body Contouring

Deepwave uses 2.45 GHz microwaves for non-invasive localised fat management. Cooling protects the skin while automatic contact detection controls microwave delivery.

Main functions

  • Selective microwave delivery uses differences in tissue conductivity to concentrate energy in the subcutaneous fat layer.
  • A Peltier cooling system works with microwave delivery to protect the skin and maintain comfort.
  • Automatic contact detection releases microwave energy only when the handpiece directly contacts the skin.
  • Official applications include the double chin, abdomen, back, buttocks and thighs for localised fat reduction and skin firming.

Technical illustrations

Deepwave Microwave Body Contouring Technical sheet 1
Deepwave Microwave Body Contouring Technical sheet 2
Deepwave Microwave Body Contouring Technical sheet 3
Deepwave Microwave Body Contouring Technical sheet 4
Technical information in text

Deepwave microwave contouring system. Illustrated areas include the double chin and jawline, abdomen, back, buttocks and thighs, combining localised fat management with firming. The distributor claims painless, lasting and immediate results with no recovery time.

The 2.45 GHz microwave system uses differences in tissue conductivity to concentrate energy in subcutaneous fat while reducing heating of the epidermis and dermis. The brochure states energy absorption of 80% in fat and 20% in skin and shows a spectrum diagram distinguishing radiofrequency and microwaves. These are distributor descriptions. A patented cooling system provides a protective cooling barrier alongside microwave delivery.

Four features: selective local-fat targeting; patented cooling; automatic body-contact detection releasing microwaves only during direct skin contact; face and body fat-management and firming. Specifications: source, microwave; frequency/power, 2.45 GHz/120W; handpiece outer Ø66, radiating area Ø52, depth 7 mm; Peltier cooling; 10.2-inch colour touchscreen; electrical requirement, 100–240VAC, 50–60Hz, 600VA. The source prints no diameter units beside Ø66 or Ø52; none are inferred.

Deepwave full device, handpiece, trolley and branding. The graphic displays several certification marks; these images do not establish verified Hong Kong registration, local package contents or independent clinical approval.

Download the original brochure (PDF)

Equipment specifications and care accessories
Energy source
Microwave
Frequency / power
2.45 GHz / 120W
Handpiece
Outer Ø66; radiating area Ø52; depth 7 mm
Cooling system
Peltier
Interface
10.2-inch colour touchscreen
Electrical requirement
100–240VAC, 50–60Hz, 600VA